The signal is processed by a multiple signal analysis method which guarantees excellent sensitivity and a high immunity to false alarms. Detection analysis can be adjusted to increase its immunity (if installed in a problematic location). The detector distinguishes itself with excellent immunity against high frequency interference and other unwanted signals. It can be installed on a flat wall or in a corner.
Power supply: | 12 V DC ± 25% |
---|---|
Standby consumption (LED off): | max. 3 mA |
Maximum consumption(LED on): | max. 7 mA |
Terminal size: | 1 mm2 |
Recommended installation height | 1.2 m above floor level |
Detection angle/range | 120° / 12 m (with basic lens) |
Initialisation: | max. 60 s |
Pulse output length of PIR: | 2 s |
Alarm output: | NC max. 60V / 100mA Internal resistance max. 30 Ohm |
Tamper output: | NC max. 60 V / 100mA Internal resistance max. 30 Ohm |
Environment to EN 50131-1 | II. Indoor general |
Operational temperature | -10 to +40 °C |
Dimensions | 180 x 60 x 55 mm |
EN 50131-1, CLC/TS 50131-2-2, EN 50131-5-3 classification |
grade 2 (medium risk) |
Also complies with: | ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1 |