phone: 68 411 40 56, 887 265 866 | |
e-mail: systemygsm.pl@gmail.com | |
GG: 59620 Skype: siwycyfra |
The JA-80Z signal repeater can extend the range of remote devices whose signal is not strong enough to communicate with the control panel or whose communication is unreliable. .
The repeater function lies in the retransmission of a signal received from an enrolled device with a little delay. The delay ensures that a possible conflict between the repeater transmission and the transmitting device is avoided. Each device enrolled to the repeater must concurrently be enrolled to the control panel
A double-balanced INP input with a selectable natural reaction (default: delayed loop) is available for the connection of one hard-wire detector. Activation of this input is transmitted to the control panel as a signal from a device to which the repeater has been enrolled in the control panel. The reaction of this loop can be configured in the control panel.
The repeater front cover is protected with a built-in tamper sensor and the box must be protected against being torn off the wall with a tamper device delivered with the package.
The repeater must be equipped with a backup battery (e.g. SA-214/1,3) which ensures its operation when there is a power supply failure
Frequency | 868 MHz |
EMC | EN 50130-4, EN 55022 |
Number of addresses for wireless devices | 40 |
Number of wired input | 1x double balanced input (one input reserved for the rear tamper contact) |
Safety level | 2 (according to EN50131-1, EN 50131-6 and EN 50131-5-3) |
Working environment | II. indoor-general (-10 to +40°C) compliant with EN 50131-1 |
Indoor siren output IW* | switching to GND, max. 0.5 A |
Outdoor siren output EW* | switching to GND, max. 0.5 A |
Power supply | 230 V / 50 Hz, max 0.1A, CLASS PROTECTION II |